10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.

10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.
  • Model:
    Growatt10000HYP
  • Phase:
    3-phase in / 3-phase out
  • Rated Output Power:
    10000 W
  • Max. Charging Power:
    9600 W
  • AC Output Volt.:
    230/400 VAC
  • DC MPP Volt.:
    350~ 850 VDC

10KW three phase on-grid inverter with energy storage,Self-consumption and Feed-in to the grid,Programmable supply priority for PV, Battery or Grid,User-adjustable charging current up to 200A.

description

10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.

 

Features:
• 10KW three phase on-grid inverter with energy storage.
• Self-consumption and Feed-in to the grid.

• Parallel operation with up to 3 units
• Programmable supply priority for PV, Battery or Grid.
• User-adjustable charging current up to 200A.
• Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup.
• Built-in timer for various mode of on/off operation.
• Multiple communication for USB, RS-232, Modbus and SNMP.

• Monitoring software for real time status display and control.

 

Datasheet:

Model Growatt 3000HY Growatt 5000HYP Growatt 10000HYP
 PHASE 1-phase in/1-phase out 3-phase in/3-phase out
 RATED OUTPUT POWER 3000 W 5000 W 10000 W
 MAXIMUM CHARGING POWER 1200 W 4800 W 9600 W
 GRID-TIE OPERATION
 PV INPUT (DC)
 Maximum PV Input Power 4500W 10000W 14850W
 Nominal DC Voltage / Maximum DC Voltage 360 VDC / 500 VDC 720 VDC / 900 VDC 720 VDC / 900 VDC
 Start-up Voltage / Initial Feeding Voltage 116 VDC / 150 VDC 225 VDC / 250 VDC 320 VDC / 350 VDC
 MPP Voltage Range 250 VDC ~ 450 VDC 250 VDC ~ 850 VDC 350 VDC ~ 850 VDC
 No. of MPP Trackers / Max.Input Current 1 / 1 x 18 A 2 / 2 x 10A 2 / 2 x 18.6A
 GRID OUTPUT (AC)
  Nominal Output Voltage 208/220/230/240 VAC 230VAC (P-N) /400VAC (P-P)
  Output Voltage Range 184 – 264.5 VAC* 184 – 265.5 VAC* 184-265 VAC per phase
  Nominal Output Current 13 A 21A 14.5 A per phase
  Power Factor >0.99  >0.99 >0.99
 EFFICIENCY
  Maximum Conversion Effciency (DC/AC) 96% 96% 96%
  European Effciency @ Vnominal 95% 95% 95%
 OFF-GRID OPERATION
  AC INPUT
  AC Start-up Voltage/Auto Restart Voltage 120 – 140 VAC / 180 VAC 120-140 VAC/180 VAC per phase
  Acceptable Input Voltage Range 170 – 280 VAC 170 – 280 VAC 170-280 VAC per phase
  Maximum AC Input Current 30 A 40 A 25 A
  PV INPUT (DC)
  Maximum DC Voltage 500 VDC 900 VDC 900 VDC
  MPP Voltage Range 250 VDC ~ 450 VDC 250 VDC ~ 850 VDC 350 VDC ~ 850 VDC
 No. of MPP Trackers/Max. Input Current  1 / 1 x 18 A  2 / 2 x 10A 2 / 2 x 18.6A
 BATTERY MODE OUTPUT (AC)
 Nominal Output Voltage 202/208/220/230/240 VAC 230 VAC (P-N)/400 VAC (P-P)
 Output Waveform Pure Sinewave Pure Sinewave Pure Sinewave
 Effciency (DC to AC)  93%  91%   91%
 HYBRID OPERATION
 PV INPUT (DC)
 Nominal DC Voltage / Maximum DC Voltage 360 VDC / 500 VDC 720 VDC / 900 VDC  720 VDC / 900 VDC
 Start-up Voltage / Initial Feeding Voltage 116 VDC / 150 VDC 220 VDC / 250 VDC 320 VDC / 350 VDC
 MPP Voltage Range  250 VDC ~ 450 VDC 250 VDC ~ 850 VDC  350 VDC ~ 850 VDC
 No. of MPP Trackers/Max. Input Current  1 / 1 x 18 A 2 / 2 x 10A  2 / 2 x 18.6A
 GRID OUTPUT (AC)
 Nominal Output Voltage  202/208/220/230/240 VAC 230 VAC (P-N) /400 VAC (P-P)
 Output Voltage Range  184 – 264.5 VAC*  184 – 265.5 VAC* 184 – 265 VAC per phase
 Nominal Output Current  13 A 21 A  14.5 A per phase
 AC INPUT
 AC Start-up Voltage / Auto Restart Voltage  120 – 140 VAC / 180 VAC 120 – 140 VAC per phase / 180 VAC per phase
 Acceptable Input Voltage Range  170 – 280 VAC 170 – 280 VAC per phase
 Maximum AC Input Current  30 A 40 A  25A
 BATTERY MODE OUTPUT (AC)
 Nominal Output Voltage  202/208/220/230/240 VAC 230 VAC (P-N) /400 VAC (P-P)
 Effciency (DC to AC)  93%  91%  91%
 BATTERY & CHARGER
 Nominal DC Voltage  48 VDC 48 VDC  48 VDC
 Maximum Charging Current  25A  100A Default 60A, 5A – 200A (Adjustable)
 GENERAL
 PHYSICAL
 Dimension (D*W*H MM)  107*438*480  204*460*600 622*500*167.5
 Net Weight (KGS) 15.5 29  45
 INTERFACE
 Communication Port  RS-232/USB  RS-232/USB RS-232/USB and CAN Interface
 Intelligent Slot Optional SNMP, Modbus, and AS-400 cards available
 ENVIRONMENT
 Humidity 0 ~ 90% RH (No condensing)
 Operating Temperature 0 to 40°C -10 to 55°C -10 to 55°C
 Altitude 0 ~ 1000 m* 0 ~ 1000 m* 0 ~ 1000 m*
 Certificates VDE-AR-N 4105,VDE 0126-1-1,AS 4777 , AS/NZS3100

*These fgures may vary depending on different AC voltage and country requirements.

*Power derating 1% every 100 m when altitude is over 1000m.
*Product specifcations are subject to change without further not ice.

send us your 10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.