10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.
-
Model:Growatt10000HYP
-
Phase:3-phase in / 3-phase out
-
Rated Output Power:10000 W
-
Max. Charging Power:9600 W
-
AC Output Volt.:230/400 VAC
-
DC MPP Volt.:350~ 850 VDC
10KW three phase on-grid inverter with energy storage,Self-consumption and Feed-in to the grid,Programmable supply priority for PV, Battery or Grid,User-adjustable charging current up to 200A.
description
10KW 48V 200A Hybrid Pure Sine Power Inverter Built In Solar / AC Charge / AC Bypass Mode. Auto or Manual Switch between DC or AC priority first.
Features:
• 10KW three phase on-grid inverter with energy storage.
• Self-consumption and Feed-in to the grid.
• Parallel operation with up to 3 units
• Programmable supply priority for PV, Battery or Grid.
• User-adjustable charging current up to 200A.
• Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup.
• Built-in timer for various mode of on/off operation.
• Multiple communication for USB, RS-232, Modbus and SNMP.
• Monitoring software for real time status display and control.
Datasheet:
Model | Growatt 3000HY | Growatt 5000HYP | Growatt 10000HYP |
PHASE | 1-phase in/1-phase out | 3-phase in/3-phase out | |
RATED OUTPUT POWER | 3000 W | 5000 W | 10000 W |
MAXIMUM CHARGING POWER | 1200 W | 4800 W | 9600 W |
GRID-TIE OPERATION | |||
PV INPUT (DC) |
|||
Maximum PV Input Power | 4500W | 10000W | 14850W |
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers / Max.Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 208/220/230/240 VAC | 230VAC (P-N) /400VAC (P-P) | |
Output Voltage Range | 184 – 264.5 VAC* | 184 – 265.5 VAC* | 184-265 VAC per phase |
Nominal Output Current | 13 A | 21A | 14.5 A per phase |
Power Factor | >0.99 | >0.99 | >0.99 |
EFFICIENCY | |||
Maximum Conversion Effciency (DC/AC) | 96% | 96% | 96% |
European Effciency @ Vnominal | 95% | 95% | 95% |
OFF-GRID OPERATION | |||
AC INPUT | |||
AC Start-up Voltage/Auto Restart Voltage | 120 – 140 VAC / 180 VAC | 120-140 VAC/180 VAC per phase | |
Acceptable Input Voltage Range | 170 – 280 VAC | 170 – 280 VAC | 170-280 VAC per phase |
Maximum AC Input Current | 30 A | 40 A | 25 A |
PV INPUT (DC) | |||
Maximum DC Voltage | 500 VDC | 900 VDC | 900 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers/Max. Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N)/400 VAC (P-P) | |
Output Waveform | Pure Sinewave | Pure Sinewave | Pure Sinewave |
Effciency (DC to AC) | 93% | 91% | 91% |
HYBRID OPERATION | |||
PV INPUT (DC) | |||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 220 VDC / 250 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers/Max. Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N) /400 VAC (P-P) | |
Output Voltage Range | 184 – 264.5 VAC* | 184 – 265.5 VAC* | 184 – 265 VAC per phase |
Nominal Output Current | 13 A | 21 A | 14.5 A per phase |
AC INPUT | |||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | 120 – 140 VAC per phase / 180 VAC per phase | |
Acceptable Input Voltage Range | 170 – 280 VAC | 170 – 280 VAC per phase | |
Maximum AC Input Current | 30 A | 40 A | 25A |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N) /400 VAC (P-P) | |
Effciency (DC to AC) | 93% | 91% | 91% |
BATTERY & CHARGER | |||
Nominal DC Voltage | 48 VDC | 48 VDC | 48 VDC |
Maximum Charging Current | 25A | 100A | Default 60A, 5A – 200A (Adjustable) |
GENERAL | |||
PHYSICAL | |||
Dimension (D*W*H MM) | 107*438*480 | 204*460*600 | 622*500*167.5 |
Net Weight (KGS) | 15.5 | 29 | 45 |
INTERFACE | |||
Communication Port | RS-232/USB | RS-232/USB | RS-232/USB and CAN Interface |
Intelligent Slot | Optional SNMP, Modbus, and AS-400 cards available | ||
ENVIRONMENT | |||
Humidity | 0 ~ 90% RH (No condensing) | ||
Operating Temperature | 0 to 40°C | -10 to 55°C | -10 to 55°C |
Altitude | 0 ~ 1000 m* | 0 ~ 1000 m* | 0 ~ 1000 m* |
Certificates | VDE-AR-N 4105,VDE 0126-1-1,AS 4777 , AS/NZS3100 |
*These fgures may vary depending on different AC voltage and country requirements.
*Power derating 1% every 100 m when altitude is over 1000m.
*Product specifcations are subject to change without further not ice.