Hinergy 5KW Hybrid Solar Power Inverter Grid Tied and Off Grid Solar Inverter Solar Power 5KVA China Supplier
-
Model:Growatt 5000HYP
-
Phase:1-phase in / 1-phase out
-
Rated Output Power:5000 W
-
Max. Charging Power:4800 W
-
AC Output:208/220/230/240V
-
DC MPP Volt.:250~ 850 VDC
5KW single phase on-grid inverter with energy storage.Parallel operation with up to 6 units.Programmable supply priority for PV, Battery or Grid.
description

Hinergy 5KW Hybrid Solar Power Inverter Grid Tied and Off Grid Solar Inverter Solar Power 5KVA China Supplier
Features:
• 5KW single phase on-grid inverter with energy storage.
• Self-consumption and Feed-in to the grid.
• Parallel operation with up to 6 units
• Programmable supply priority for PV, Battery or Grid.
• User-adjustable charging current up to 200A.
• Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup.
• Built-in timer for various mode of on/off operation.
• Multiple communication for USB, RS-232, Modbus and SNMP.
• Monitoring software for real time status display and control.
Datasheet:
Model | Growatt 3000HY | Growatt 5000HYP | Growatt 10000HYP |
PHASE | 1-phase in/1-phase out | 3-phase in/3-phase out | |
RATED OUTPUT POWER | 3000 W | 5000 W | 10000 W |
MAXIMUM CHARGING POWER | 1200 W | 4800 W | 9600 W |
GRID-TIE OPERATION | |||
PV INPUT (DC) |
|||
Maximum PV Input Power | 4500W | 10000W | 14850W |
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers / Max.Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 208/220/230/240 VAC | 230VAC (P-N) /400VAC (P-P) | |
Output Voltage Range | 184 – 264.5 VAC* | 184 – 265.5 VAC* | 184-265 VAC per phase |
Nominal Output Current | 13 A | 21A | 14.5 A per phase |
Power Factor | >0.99 | >0.99 | >0.99 |
EFFICIENCY | |||
Maximum Conversion Effciency (DC/AC) | 96% | 96% | 96% |
European Effciency @ Vnominal | 95% | 95% | 95% |
OFF-GRID OPERATION | |||
AC INPUT | |||
AC Start-up Voltage/Auto Restart Voltage | 120 – 140 VAC / 180 VAC | 120-140 VAC/180 VAC per phase | |
Acceptable Input Voltage Range | 170 – 280 VAC | 170 – 280 VAC | 170-280 VAC per phase |
Maximum AC Input Current | 30 A | 40 A | 25 A |
PV INPUT (DC) | |||
Maximum DC Voltage | 500 VDC | 900 VDC | 900 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers/Max. Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N)/400 VAC (P-P) | |
Output Waveform | Pure Sinewave | Pure Sinewave | Pure Sinewave |
Effciency (DC to AC) | 93% | 91% | 91% |
HYBRID OPERATION | |||
PV INPUT (DC) | |||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | 220 VDC / 250 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
No. of MPP Trackers/Max. Input Current | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A |
GRID OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N) /400 VAC (P-P) | |
Output Voltage Range | 184 – 264.5 VAC* | 184 – 265.5 VAC* | 184 – 265 VAC per phase |
Nominal Output Current | 13 A | 21 A | 14.5 A per phase |
AC INPUT | |||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | 120 – 140 VAC per phase / 180 VAC per phase | |
Acceptable Input Voltage Range | 170 – 280 VAC | 170 – 280 VAC per phase | |
Maximum AC Input Current | 30 A | 40 A | 25A |
BATTERY MODE OUTPUT (AC) | |||
Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N) /400 VAC (P-P) | |
Effciency (DC to AC) | 93% | 91% | 91% |
BATTERY & CHARGER | |||
Nominal DC Voltage | 48 VDC | 48 VDC | 48 VDC |
Maximum Charging Current | 25A | 100A | Default 60A, 5A – 200A (Adjustable) |
GENERAL | |||
PHYSICAL | |||
Dimension (D*W*H MM) | 107*438*480 | 204*460*600 | 622*500*167.5 |
Net Weight (KGS) | 15.5 | 29 | 45 |
INTERFACE | |||
Communication Port | RS-232/USB | RS-232/USB | RS-232/USB and CAN Interface |
Intelligent Slot | Optional SNMP, Modbus, and AS-400 cards available | ||
ENVIRONMENT | |||
Humidity | 0 ~ 90% RH (No condensing) | ||
Operating Temperature | 0 to 40°C | -10 to 55°C | -10 to 55°C |
Altitude | 0 ~ 1000 m* | 0 ~ 1000 m* | 0 ~ 1000 m* |
Certificates | VDE-AR-N 4105,VDE 0126-1-1,AS 4777 , AS/NZS3100 |
*These fgures may vary depending on different AC voltage and country requirements.
*Power derating 1% every 100 m when altitude is over 1000m.
*Product specifcations are subject to change without further not ice.
send us your Hinergy 5KW Hybrid Solar Power Inverter Grid Tied and Off Grid Solar Inverter Solar Power 5KVA China Supplier